3 access error stack frame additions, Access error stack frame additions -8, Section 5.4.3, “access error stack frame additions – Freescale Semiconductor MCF5480 User Manual

Page 174

Advertising
background image

MCF548x Reference Manual, Rev. 3

5-8

Freescale Semiconductor

In addition, the following two privileged M68000 family instructions to load/store the USP are added to

the ColdFire instruction set architecture:

mov.l

Ay,USP

# move to USP: opcode = 0x4E6{0-7}

mov.l

USP,Ax

# move from USP: opcode = 0x4E6{8–F}

The address register number is encoded in the three low-order bits of the opcode.
These instructions are described in detail in

Section 5.7, “MMU Instructions

.”

5.4.3

Access Error Stack Frame Additions

ColdFire exceptions generate a standard 2-longword stack frame, signaling the contents of the SR and PC

at the time of the exception, the exception type, and a 4-bit fault status field (FS). The first longword

contains the 16-bit format/vector word (F/V) and the 16-bit status register. The second contains the 32-bit

program counter address of the faulted instruction.

The FS field is used for access and address errors. To optimize TLB miss exception handling, new FS

encodings (

Table 5-2

) allow quick error classification.

31

28

27

26

25

18

17

16

15

0

A7

FORMAT

FS[3–2]

VEC[7–0]

FS[1–0] STATUS

REGISTER

+ 0x04

PROGRAM COUNTER [31–0]

Figure 5-2. Exception Stack Frame

Table 5-2. Fault Status Encodings

FS[3:0]

Definition

0000

Not an access or address error

0001, 001x

Reserved

0100

Error (for example, protection fault) on instruction fetch

0101

TLB miss on opword of instruction fetch (New in CF4e)

0110

TLB miss on extension word of instruction fetch (New in CF4e)

0111

IFP access error while executing in emulator mode (New in CF4e)

1000

Error on data write

1001

Attempted write of protected space

1010

TLB miss on data write (New in CF4e)

1011

Reserved

1100

Error on data read

1101

Attempted read, read-modify-write of protected space (New in CF4e)

1110

TLB miss on data read, or read-modify-write (New in CF4e)

1111

OEP access error while executing in emulator mode (New in CF4e)

Advertising