Chapter 3 Operation

91

[2] Operation Mode (RMOD, RMDS)

Input

Output

PIO signal

RMOD

RMDS

Common to

Patterns 0 to 7

: Available, �: Unavailable

Two operation modes are provided so that the operation by PIO signals does not overlap with

the operation by a teaching tool such as PC software through SIO (serial) communication.

The mode change is normally done by the operation mode setting switch ON the front panel of

the controller.

AUTO··········Operation by PIO signals is valid.

MANU·········Operation through SIO (serial) communication is valid.

However, when having the controller in link connection

(Note 1)

and the teaching tool such as PC

software being connected using SIO converter, there is a case the controller and the teaching

tool are placed far from each other. In such a case, the controller can be entered into the MANU

mode by setting PIO signal RMOD to ON.

Because the RMDS signal is set to ON with the MANU mode selected by using the signal,

make the operation sequence interlocked.

The table below lists the switches ON the front panel, the modes selected by the RMOD signal

and the corresponding output states of the RMDS signal.

Note 1: For the details of the link connection, refer to “10.2 Way to Set Multiple Controllers

with 1 Teaching Tool”.

: Selected or set to ON

Condition

Status

PIO Operation

Invalid

(Note 2)

Teaching tool such as

PC software

PIO Operation

Allowed

(Note 2)

AUTO

Switches ON

front panel

MANU

PIO Input

RMOD

PIO Output

RMDS

PIO valid: �, PIO invalid:�

Note 2: “PIO Operation Allowed” or “PIO Operation Invalid” is the function to select a

restriction while the teaching tool such as PC software is connected.

� �

Caution: (1) Note that selecting “PIO Operation Allowed” by using the teaching tool

such as PC software makes all PIO signals valid to enable operation

however the states of the switches and RMOD signal input may be. In

this status, the actuator may be started depending on the signals from

PLC.

(2) If the teaching tool such as PC software is disconnected from the

controller, “PIO Operation Allowed” or “PIO Operation Invalid” holds

the state selected before. After teaching operation or debugging is

terminated, select “PIO Operation Allowed” and disconnect the

teaching tool such as PC software from the controller.

Operation by normal PIO