2) Calculation of Continuous Operation Thrust

Figure out the continuous operation thrust F

t

by following the formula.

First, check the operation pattern of t

1a

/t

1d

/t

2a

/t

2d

to find out that

Arrival speed (Vmax) = 0.05 × 0.098 � 0.07m/s and,

therefore it is greater than the set speed 62mm/s (0.06m/s), thus the pattern is the trapezoid

type.

Therefore, t

1a

/t

1d

/t

2a

/t

2d

= 0.062/0.098 � 0.63s.

Secondary, if calculating t

1f

/t

2f

;

Rated speed movement distance = 0.05 – {(0.062 Ч 0.062) / (2 Ч 0.098)} Ч 2 � 0.011m, thus

t

1f

/t

2f

= 0.011 / 0.062 � 0.17s

Also, if calculating F

1a

/F

1f

/F

1d

/F

2a

/F

2f

/F

2d

from the formula;

F

1a

= F

2d

= (9 + 100) Ч 9.8 – (9 + 100) Ч 0.098 � 1058N

F

1d

= F

2a

= (9 + 100) Ч 9.8 + (9 + 100) Ч 0.098 � 1079N

F

1f

= F

2f

= f

w

= (9 + 100) × 9.8 � 1068N

If substituting the values above to the continuous operation thrust formula;

F

t

=

F

1a

2

× t

1a

+ F

1f

2

× t

1f

+ F

1d

2

× t

1d

+ F

0

2

× t

0

+ F

2a

2

× t

2a

+ F

2f

2

× t

2f

+ F

2d

2

× t

2d

+ F

w

2

× t

w

t

=

{(1058 Ч 1058) Ч 0.63 + (1068Ч1068) Ч 0.17 + (1079 Ч 1079) Ч 0.63 + (19600 Ч 19600) Ч

3 + (1079 Ч 1079) Ч 0.63 + (1068 Ч 1068) Ч 0.17 + (1058 Ч 1058) Ч 0.63 + (1068 Ч 1068) Ч 2}

/ (0.63 + 0.17 + 0.63 + 3 + 0.63 + 0.17 + 0.63 + 2) � 12113N

Since the answer exceeds 10200N, which is the rated thrust of Ultra-High Thrust Actuator 2

tone type, the operation is not allowed with this operation pattern.

Now, try to extend the standby time (to lower the duty).

In this case, F

t

= 9814N assuming t

w

= 6.12s (t = 12s), thus the operation is available.

Advertising