Chapter 2 Wiring

39

2.1.2 PIO Pattern Selection and PIO Signal

(1) PIO Pattern (Control Pattern) Selection

The controller provides eight PIO patterns (control patterns). Set the most suitable PIO pattern

with the actual use to Parameter No. 25 “PIO Pattern Select”.

Refer to “3.2 Operation in Positioner Mode” for the details of PIO patterns.

Type

Value set in

parameter

No. 25

Mode

Overview

PIO

Pattern 0

0

(at the

delivery)

Positioning Mode

(Standard Type)

�

Number of positioning points : 64 points

�

Position command : binary code

�

Zone signal output

*1

: 1 point

�

Position zone signal output

*2

: 1 point

PIO

Pattern 1

1

Teaching mode

(Teaching type)

�

Number of positioning points : 64 points

�

Position command : binary code

�

Position zone signal output

*2

: 1 point

�

Jog operation enabled by PIO signal

�

Writing current position data to position table

enabled by PIO signal

PIO

Pattern 2

2

256-point mode

(Number of

positioning points :

256-point type)

�

Number of positioning points : 256 points

�

Position command : binary code

�

Position zone signal output

*2

: 1 point

PIO

Pattern 3

3

512-point mode

(Number of

positioning points :

512-point type)

�

Number of positioning points : 512 points

�

Position command : binary code

�

Zone signal output : None

PIO

Pattern 4

4

Solenoid Valve

Mode 1

(7-point type)

�

Number of positioning points : 7 points

�

Position command : Individual number signal ON

�

Zone signal output

*1

: 1 point

�

Position zone signal output

*2

: 1 point

PIO

Pattern 5

5

Solenoid Valve

Mode 2

(3-point type)

�

Number of positioning points : 3 points

�

Position command : Individual number signal ON

�

Completion signal : Signal equivalent to LS

(limit switch) enabled

�

Zone signal output

*1

: 1 point

�

Position zone signal output

*2

: 1 point

PIO

Pattern 6

6

Pressing

Operation Using

Force Sensor

Mode 1

�

Number of positioning points : 32 points

�

Position command : binary code

�

Position zone signal output

*2

: 1 point

�

Judgment of pressing force enabled

PIO

Pattern 7

7

Pressing

Operation Using

Force Sensor

Mode 2

(Solenoid Valve Type)

�

Number of positioning points : 5 points

�

Position command : Individual number signal ON

�

Position zone signal output

*2

: 1 point

�

Judgment of pressing force enabled

*1 Zone signal output

: Set the zone range in parameter No.1 and 2. The signal is

always effective after home return is completed.

*2 Position zone signal output : This feature is associated with the specified position number.

The zone range is set in the position table. The zone range is

enabled only when the position is specified but disabled if

another position is specified.

Position Zone Signal can be changed to Zone Signal in

Parameter No.149.