Chapter 8 I/O Parameter

225

[84] Monitoring period (Parameter No.113)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

113 Monitoring period

FMNT

msec

1 to 100

1

This is the parameter to set up the frequency of time to obtain data (Sampling Frequency) when

the monitoring mode is selected.

By setting the value in this parameter bigger, the frequency of data obtaining can be made

longer.

It is set to 1ms in the initial setting. Up to 100ms can be set.

1ms frequency setting

100ms frequency setting

Up to 30 seconds in 4CH-30000

record mode

Up to 3000 seconds (50 minutes)

in 4CH-30000 record mode

Up to 15 seconds in 8CH-15000

record mode

Up to 1500 seconds (25 minutes)

in 8CH-15000 record mode

[85] Selecting used feedback pulse gear ratio (Parameter No.114)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

114 Selecting used feedback pulse

gear ratio

FPIO

0: Not Applicable

1: Use

0

Refer to 3.3.5 Output Settings of Feedback Pulse when using the product with Pulse Train

Control Mode.

Feedback pulse is available for the output also other than Pulse Train Control Mode. In this

case, select “1”.

Set Value

Description

0

Outputs feedback pulses using the electronic gear ratio

defined by parameter No.65 and 66 (command pulse-train)

(initial value)

1

Outputs feedback pulses using the electronic gear ratio

defined by parameter No.115 and 116.

[86] Electrical Gear (Feedback Pulse) (Parameter No.115, No.116)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

115 Electronic Gear Denominator

FDEN

1 to 4096

2048

116 Electronic Gear Numerator

FNUM

1 to 4096

125

Refer to 3.3.5 Output Settings of Feedback Pulse for the details.

The setting is the same for the cases other than Pulse Train Control Mode.