IAI America SCON-CA User Manual

Page 98

Advertising
background image

Chapter 3 Operation

88

12) Incremental···············Set to 1 for pitch feed (relative movement = incremental feed).

The value set for the position in 1) indicates the pitch feed distance.

With the value set to 0, positioning is defined to the position in 1)

based on the absolute coordinate system.

� �

Caution: In the pitch feed, do not perform a command with a pitch smaller than the

minimum encoder resolution (lead/encoder pulse number) or that less than

positioning accuracy repeatability.

There would be no deviation to occur even with the command because it is an

operation command to the same position as the positioning complete

condition, but the positioning control cannot be performed properly.

When solenoid valve mode 2 is selected, set this to 0. Setting this to 1 causes

the position data error to occur.

13) Gain set····················Six parameters required for servo gain adjustment are collected to be

a single set. Up to four sets can be registered to change the servo

gain in positioning.

By utilizing Off Board Tuning Function

(Note)

in the PC software, the

setting close to the optimum can be obtained.

(Note) Refer to Section 10 Appendix Connectable Actuators for the

applicable models.

It may require the setting of the gain set dedicated for the

home-return operation in the case this function is used to

have the high-speed setting or the setting to apply a

transported weight more than the ratings.

For how to set up and the caution items, refer to the

instruction manual for RC PC Software.

[Parameters included in a set:]

Servo gain number (Position Gain)

Position feed forward gain

Speed Loop Proportional Gain

Speed Loop Integral Gain

Torque Filter Time Constant

Current control band number

It is able to establish the gain set that corresponds to the position

number to be operated to the indicated gain set.

[Refer to “Servo Adjustment” in Section 8.3 for each gain parameter details.]

Setting

Selected parameter set

Parameter No.

0

Gain set 0

7, 71, 31 to 33, 54

1

Gain set 1

120 to 125

2

Gain set 2

126 to 131

3

Gain set 3

132 to 137

Advertising