Chapter 5 V

ibration Suppress Control Function

181

[4] Default vibration suppress No. (Parameter No.109)

When a position is written into a position table not registered yet, the value set to this

parameter is automatically entered in the “Vibration suppress No.” field. To change the

setting, edit the position table later.

0: Normal position control (default)

1: Vibration suppress control parameter set 1

2: Vibration suppress control parameter set 2

3: Vibration suppress control parameter set 3

[5] Stop method at servo OFF (Parameter No.110)

The table below shows the relationship between the values of Parameter No.110 and stop

commands.

5.3 Setting of Position Data

To make the anti-vibration control effective, set the parameter set number to be used in

Anti-Vibration Number Column in Position Data.

(Note) The vibration suppress control function cannot be used in pressing operation.

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width
[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Gain

set

Stop

mode

Vibration

suppress

No.

0

1

0.00

50.00

0.01

0.01

0

0

0.10

0.00

0.00

0

0

0

0

0

2

50.00

50.00

0.01

0.01

0

0

0.10

0.00

0.00

0

0

0

0

1

3

50.00

50.00

0.01

0.01

50

0

0.10

0.00

0.00

0

0

0

0

3

4

Stop Process

0

1

Stop Command

Vibration

suppress

control

Normal

positioning

control

Vibration

suppress

control

Normal

positioning

control

Pause

Deceleration

by vibration

suppress and

stop

Normal

deceleration

and stop

Servo OFF

Emergency Stop

Error

(Operation-cancellation

level alarms)

Sudden stop by

emergency stop torque

Deceleration

by vibration

suppress and

stop

Normal

deceleration

and stop

Error

(Cold start)

Sudden stop due to emergency stop torque

Set natural frequency 1 (valid)

Set natural frequency 3 (It cannot be in common

with Error: 0A2 Position Data Error Pressing

Operation.)

Advertising