Troubleshooting

247

Alarm

Code

Alarm

Level

Alarm Name

Cause/Treatment

080

Move command in servo

OFF

Cause

: A move command was issued when the servo is

OFF.

Treatment : Issue a movement command after confirming the

servo is ON (servo ON signal (SV) or position

complete signal (PEND) is ON).

082

Position command in

incomplete home return

Cause

: A position move command was issued before home

return was completed.

Treatment : Issue a command after confirming that home return

has been completed (HEND) is ON.

083

Numerical command in

incomplete home return

Cause

: An absolute position command was issued by

numerical specification before home return was

completed (direct command from Field Network).

Treatment : Issue a numeric specification after performing home

return operation and confirming the complete signal

(HEND).

084

Absolute position move

command when home

return is not yet completed

Cause

: A move command was issued when home return

was still in progress.

Treatment : Issue a movement command after performing home

return operation and confirming the complete signal

(HEND).

085

Position No. error during

movement

Cause

: A non-existing (invalid) position number was

specified in the positioner mode.

Treatment : Check the position table again and indicate an

effective position number.

086

Move command while

pulse train input is

effective

Cause

: Actuator operation was commanded via serial

communication in pulse train mode.

Treatment : Stop the actuator operation command via serial

communication in pulse train mode.

087

Moving command during

loadcell calibration

Cause

: A move command was issued during loadcell

calibration.

Treatment : After confirming the loadcell calibration is

completed with the calibration complete (CEND)

signal, and confirming CLBR Signal is turned OFF,

perform the movement command.

090

Software reset during

servo ON

Cause

: A software reset command was issued when the

servo was ON.

Treatment : Issue a software reset command after confirming

that the servo is OFF (SV signal is 0).

091

Position No. error in

teaching

Cause

: The position number out of the available range was

selected in the teaching.

Treatment : Select the position number from 63 or smaller.

092

PWRT signal detection

during movement

Cause

: The current position write signal (PWRT) was input

in the teaching mode of PIO pattern 1 while the

actuator was jogging.

Treatment : Input the PWRT signal after confirming that the job

button is not pressed and the actuator is stopped

(MOVE output signal is OFF).

093

Operation

release

PWRT signal detection in

incomplete home return

Cause

: The current position write signal (PWRT) was input

in the teaching mode of PIO pattern 1 when home

return was not yet completed.

Treatment : Input the HOME signal first to perform home return,

and then input the PWRT signal after confirming

that the home return has completed (HEND output

signal is ON).

Advertising