Chapter 8 I/O Parameter

196

I/O Parameter List (Continued)

No.

C

at

eg

or

y

Name

Symbol Unit

(Note1)

Input Range

Default factory

setting

for

Positioner

Mode

for Pulse

Train

Mode

Relevant

sections

66 B Electronic Gear Denominator

CDEN

1 to 4096

125

3.3.4

67 B Compulsory Stop Input

FPIO

0: Enabled,

1: Disabled

0

3.3.6

68 B Feedback Pulse Output

FPIO

0: Enabled,

1: Disabled

1

3.3.5

69 B Feedback Pulse Train

FBPT

0 to 2

0

(A/B Phase Pulse

String)

3.3.5

70 B Feedback Pulse Form Polarity

FBPT

0: Positive Logic

1: Negative Logic

0

3.3.5

71 B Feed forward gain

PLFG

0 to 100

0

8.2 [57]

8.3

72 E Timer period for emergency stop relay

fusing monitor

EMWT

msec

0 to 60000

3000

8.2 [58]

73 D Encoder voltage level

EVLV

0 to 3

Depending on

encoder cable

length

(Note2)

8.2 [59]

74 C PIO Power Supply Supervision

FPIO

0: Enabled,

1: Disabled

0

8.2 [60]

75 D Electromagnetic brake power monitor

FSTP

0: Disabled,

1: Enabled

In accordance with

actuator

(Note2)

8.2 [61]

76 D Belt breaking sensor input polarity

AIOF

0 to 2

In accordance with

actuator

(Note2)

8.2 [62]

77 D Ball Screw Lead Length

LEAD

mm

0.01 to 999.99

In accordance with

actuator

(Note2)

8.2 [63]

78 D Axis operation type

ATYP

0: Line Axis

1: Rotary Axis

In accordance with

actuator

(Note2)

8.2 [64]

79 B Rotary axis mode selection

ATYP

0: Normal Mode

1: Index Mode

In accordance with

actuator

(Note2)

8.2 [65]

80 B Rotational axis shortcut selection

ATYP

0: Disabled,

1: Enabled

In accordance with

actuator

(Note2)

8.2 [66]

84 A Field bus operation mode

(Note4)

FMOD

0 to 8

Separate volume

Separate

volume

85 A Field Bus Node Address

(Note4)

NADR

0 to 127

Separate volume

Separate

volume

86 A Field bus baud rate

(Note4)

FBRS

0 to 4

Separate volume

Separate

volume

87 E Network Type

(Note4)

NTYP

0 to 7

Separate volume

Separate

volume

88 D Software limit margin

SLMA

mm

(deg)

0 to 9999.99

In accordance with

actuator

(Note2)

8.2 [71]

89 D Allowable time of exceeding torque

allowing continuous pressing

PSCT

sec

0 to 300

In accordance with

actuator

(Note2)

8.2 [72]

90 C Field I/O format

(Note4)

FPIO

0 to 3

Separate volume

Separate

volume

91 C Current limit value at stopping due to

miss-pressing

FSTP

0: Current limit value

during movement

1: Current limit value

during pressing

0

8.2 [74]

92 C Use of loadcell

FFRC

0: Not Applicable

1: Use

In accordance with

actuator

(Note2)

8.2 [75]

93 C Selection of pressing control

FFRC

0: Current limit

1: Force sensor

In accordance with

actuator

(Note2)

8.2 [76]

94 C Pressing operation using force sensor

gain

FRCG

100 to 30000

1500

8.2 [77]

95 C Force judgment margin +

FJMM

%

1 to Maximum Pressing

Force

In accordance with

actuator

(Note2)

8.2 [78]

96 C Force judgment margin -

FJML

%

1 to Maximum Pressing

Force

In accordance with

actuator

(Note2)

8.2 [78]

Note 1 The unit (deg) is for rotary actuator. It is displayed in mm in the teaching tools.

Note 2 The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.

Note 4 These parameters are exclusively used for the field network. Set the parameters according to the

Instruction Manual of each field network, a separate volume.