IAI America SCON-CA User Manual

Page 347

Advertising
background image

Chapter 10

Appendix

337

(Example)

Operational Conditions

• Used model

: Ultra-High Thrust Actuator lead 1.25 type

• Installation posture

: Vertical

• Velocity

: 62mm/s

• Acceleration

: 0.098m/s

2

(0.01G, deceleration value should be the same)

• Movement distance

: 50mm

• Load weight

: 100kg

• Pressing command value : 200% (2000kgf)

• Pressing time

: 3sec

• Standby time

: 2sec

• Pressing operation is conducted after going down for 50mm and standby for 2sec after going up

for 50mm.

And also, the operation condition for going up and down should be the same.

Looking at this operation pattern in a graph, the figure is as shown below.

Velocity V

T

Time

t

1a

t

1f

t

1d

t

0

t

2a

t

2f

t

2d

t

w

t

1G = 9.8m/s

2

1) Confirmation of Pressing Operation Time

The pressing time is 3sec while the maximum pressing time is 13sec when the pressing

command value is 200%, thus there should be no problem. It shows that there is no problem in

the pressing time.

Advertising