Chapter 8 i/o parameter, I/o parameter list (continued) – IAI America SCON-CA User Manual

Page 207

Advertising
background image

Chapter 8 I/O Parameter

197

I/O Parameter List (Continued)

No.

C

at

eg

or

y

Name

Symbol

Unit

Input Range

Default factory

setting

for

Positioner

Mode

for Pulse

Train

Mode

Relevant

sections

97 C

Damping characteristic

coefficient 1

DC11

0 to 1000

10

5.2

98 C

Damping characteristic

coefficient 2

DC21

0 to 1000

1000

5.2

99 B

Natural frequency

NP01

1/1000Hz

500 to 30000

10000

5.2

100 C

Vibrati

on

suppr

ess

pa

ra

m

et

er

s

et

1

Notch filter gain

NFG1

1 to 20000

9990

5.2

101 C

Damping characteristic

coefficient 1

DC12

0 to 1000

10

5.2

102 C

Damping characteristic

coefficient 2

DC22

0 to 1000

1000

5.2

103 B

Natural frequency

NP02

1/1000Hz

500 to 30000

10000

5.2

104 C

Vibrati

on

suppr

ess

pa

ra

m

et

er

s

et

2

Notch filter gain

NFG2

1 to 20000

9990

5.2

105 C

Damping characteristic

coefficient 1

DC11

0 to 1000

10

5.2

106 C

Damping characteristic

coefficient 2

DC21

0 to 1000

1000

5.2

107 B

Natural frequency

NP01

1/1000Hz

500 to 30000

10000

5.2

108 C

Vibrati

on

suppr

ess

pa

ra

m

et

er

s

et

3

Notch filter gain

NFG2

1 to 20000

9990

5.2

109 B Default vibration suppress No.

CTLF

0 to 3

0

5.2

110 B Stop method at servo OFF

FSTP

0: Rapid stop

1: Deceleration to stop

0

5.2

111 B Calendar function

FRTC

0: Does not use the

calendar timer

1: Use the calendar

timer

1

8.2 [82]

112 B Monitoring mode

FMNT

0: Does not use

1: Monitor function 1

2: Monitor function 2

1

8.2 [83]

113 B Monitoring period

FMNT

msec

1 to 100

1

8.2 [84]

114 B Selecting used feedback pulse gear ratio

FPIO

0: Not Applicable

1: Use

0

8.2 [85]

115 B Electrical Gear

(Feedback Pulse)

FNUM

1 to 4096

125

8.2 [86]

116 B Electronic Gear Denominator

(Feedback Pulse)

FDEN

1 to 4096

2048

8.2 [86]

117 B Automatic loadcell calibration at start

FFRC

0: Does not perform

1: Perform

1

8.2 [87]

118 B Pressing operation without completion of

loadcell calibration

FFRC

0: Disabled,

1: Enabled

0

8.2 [88]

119 B Loadcell calibration time

CLBT

msec

1 to 9999

10

8.2 [89]

120 C Servo gain number 1

PLG1

0 to 31

In accordance with

actuator

(Note2)

8.2 [5]

8.3

Note 2: The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.