Chapter 8 I/O Parameter

222

[76] Selection of pressing control (Parameter No.93)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

93 Selection of pressing control

FFRC

0: Current limit

1: Force sensor

0

This parameter defines the pressing method.

Set Value

Description

0

Pressing by current limit (when standard actuator)

1

Force sensor pressing (For the actuator with the

loadcell)

[Refer to 3.2.7 Pressing Operation Using Force Sensor Operation Ready.]

[77] Pressing operation using force sensor gain (Parameter No.94)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

94 Pressing operation using force

sensor gain

FRCG

100 to 30000

1500

This parameter defines the gain for pressing operation using force sensor. Normally this

parameter need not be changed. The gain may be adjusted when the rigidity of the pressing

target is extremely large or small.

The factory-set value is 1500.

The table below shows the relationship among the rigidity of pressing target, the response of

pressing operation using force sensor system and pressing operation using force sensor gain.

Please contact IAI in case there is a necessity of changing this setting.

Reference setting value of pressing operation using force sensor gain

Rigidity of pressing target

Hard � Rigidity � Soft

500

750

1500

1000

1500

3000

1500

2250

4500

Re

spo

nse

of

pr

es

si

ng

o

pe

ra

tio

n

us

in

g

fo

rc

e

se

ns

or

s

ys

te

m

H

ig

h

R

es

po

ns

e

L

ow

Use of loadcell

(Parameter No.92)

Selection of
pressing control

(this parameter)

Force sensor pressing

Pressing by current limit

(conventional method)

0: Does not use

1: Use

1: Force sensor

pressing

0: Pressing by

current limit

Selection of
pressing control

(this parameter)

Parameter error alarm

Pressing by current limit

(conventional method)

1: Force sencor

pressing

0: Pressing by

current limit

Advertising