Chapter 2 wiring – IAI America SCON-CA User Manual

Page 63

Advertising
background image

Chapter 2 Wiring

53

6) PIO Pattern 5 ·················Solenoid Valve Mode 2 (3-point type)

0V(NPN Type)

24V DC

Supply

1A

P24

1B

0V

Supply

24V DC(NPN Type)

24V DC(PNP Type)

2A

P24

2B

0V(PNP Type)

Start Signal 0

Start Signal 2

Start Signal 1

3A

ST0

LS0
LS1
LS2

3B

4A

ST1

4B

5A

ST2

5B

6A

6B

7A

7B

8A

ZONE1

8B

9A

BKRL

9B

10A

RMOD

RMDS

10B

Backward End Detection
Forward End Detection
Intermediate Position Detection

11A

HEND

11B

12A

12B

13A

SV

13B

Reset

14A

RES

*EMGS

14B

Servo ON

15A

SON

*ALM

*BALM

15B

16A

16B

17A

N

17B

18A

N

18B

19A

19B

20A

20B

SCON

PIO

Connector

Alarm

Servo ON Status
Emergency Stop Status

Absolute Battery

Voltage Drop Warning Output

Zone

Operating Mode Status (Manual Mode)
Home Return Completion

Brake Control Release

Operation Mode Changeover

BR- 1

RD- 1

OR- 1

YW- 1

GN- 1

BL- 1
PL- 1

GY- 1

WT- 1

BK- 1

BR- 2

RD- 2

OR- 2

YW- 2

GN- 2

BL- 2
PL- 2

GY- 2

WT- 2

BK- 2

BR- 3
RD- 3
OR- 3

GN- 3
BL- 3
PL- 3
GY- 3
WT- 3
BK- 3
BR- 4
RD- 4
OR- 4
YW- 4
GN- 4
BL- 4
PL- 4
GY- 4
WT- 4
BK- 4

PZONE

/ZONE2

Position Zone/Zone 2

“*” in codes above shows the signal of the active low. Processing occurs when an

input signal of the type is turned OFF. An output signal of the type is normally ON

in the power-on status and turned OFF at signal output.

�� Use the attached cable for the I/O connection.

Model : CB-PAC-PIO��� (��� indicates the cable length L. Example. 020 = 2m)

Half Pitch MIL Socket

HIF6-40D-1.27R (Hirose Electric)

Flat Cable (20-core) × 2

L

20A

20B

1A

1B

BK -4 (20B)

BK -2 (20A)

BR -3 (1B)

BR -1 (1A)

No connector

No connector

Advertising