Chapter 2 Wiring

45

[3] Emergency Stop Circuit

It is the example of circuit layout when an emergency switch of the touch panel teaching or the

teaching pendant is used to the emergency stop circuit of the equipment.

24V

Emergency stop

reset switch

Emergency stop

switch

Emergency stop switch

for the teaching pendant

CR1

(Note 1)

0V

MC1

CR1

CR1

S1

S2

S1

S2

1

5

8

5

8

2
3
4

1

2
3
4

1

2
3
4

1

2
3
4

EMG

A

EMG

B

CR1

(Note 1)

MC1

(Note 2)

AC100V

AC200V

System I/O

SIO connector

Emergency stop circuit

exclusive use 24V

SIO connector

connecter

System I/O

connecter

EMG+
EMG-

L1

L2

L1C
L2C

AC power supply

Motor power

cutoff relay

(Note 3)

(Note 3)

input connector

AC power supply

input connector

Motor

power supply

Control

power supply

CR1

(Note 1)

MC1

(Note 2)

AC100V

AC200V

EMG+
EMG-

L1

L2

L1C
L2C

Note 1 The power rating of the motor power-off relay turning ON/OFF with contact CR is 24V DC

and 10mA or less.

Note 2 Connect a joint such as a contactor on L1/L2 on the terminal if an external cutoff is

required on the motor driving source in order to be complied with the safety category.

Note 3 Controller automatically confirms the teaching tool is inserted.