Chapter 3 Operation

102

3.2.4 Operation with the Position No. Input = Operations of PIO Patterns 0 to 3 and 6

This section describes the methods of operations of PIO patterns 0 to 3 and 6. These patterns

provide normal controller operation methods in which the controller is operated by turning the

start signal ON after a position No. is entered.

PIO pattern 6 is dedicatedly used for pressing operation using force sensor. The pattern is

intended to operate the actuator equipped with loadcell (RCS2-RA13R) to enable highly precise

pressing control. Before the actuator can be operated, proper calibration and initialization of

parameters are required. [Refer to 3.2.7 Pressing Operation Using Force Sensor Operation

Ready]

The control methods of positioning, pitch feed, and pressing are the same as those described

before.

[1] Positioning [Basic] (PC1 to PC**, CSTR, PM1 to PM**, PEND, MOVE, LOAD, TRQS)

Input

Output

PIO signal

PC1 to PC**

CSTR PM1 to PM** PEND MOVE LOAD TRQS

PIO pattern 0

PC1 to 32

PM1 to 32

PIO pattern 1

PC1 to 32

PM1 to 32

PIO pattern 2 PC1 to 128

PM1 to 128

PIO pattern 3 PC1 to 256

PM1 to 256

PIO pattern 6

PC1 to 16

PM1 to 16

: Available, �: Unavailable

(Note) Operation without home return leads the operation based on the data of the specified

position No. after automatichome return. If one or more problems are found, interlock

by home return complete signal HEND is required.