Chapter 2 Wiring

67

� AC Power Supply Input Connector

Connector Name

AC Power Supply Input Connector

Cable Side

MSTB2-5/6-STF-5.08

Enclosed in standard package

Controller Side

MSTB2-5/6-GF-5.08

Note 1 The input power voltage cannot be changed after the delivery. Supply the power

voltage that meets the specification.

Pin No.

Signal Name

Contents

Applicable cable diameter

1

L1

Motor AC power input

2

L2

Motor AC power input

2mm

2

(AWG14)

3

L1C

Control AC power input

4

L2C

Control AC power input

0.75mm

2

(AWG18)

5

NC

Unconnected

6

PE

Protective ground line�

2mm

2

(AWG14)

Note 2 Field wiring terminals shall be marked with conductor material (Cu), insulation

temperature rating (More than 60�C) and tightening torque (0.5 ~ 0.6N•m).

� Brake Power Supply Connector

Connector Name

Brake Power Supply Connector

Cable Side

MC1.5/2-ST-3.5

Enclosed in standard package

Controller Side

MC1.5/2-G-3.5

Pin No.

Signal Name

Contents

Applicable cable diameter

BK+

24V DC power supply input

PWR-

24V DC ground

0.5mm

2

(AWG20)

BK+

PWR-

24V

0V