Chapter 1 Specifications Check

28

1.4.2 Pulse Train Input Output Interface

Line Driver Input

Output

Specification

Input pulse equivalent to Line Driver 26C31

26C31 or equiv

Controller

Output pulse equivalent to Line Receiver 26C32

26C32 or equiv

Controller

Pulse Train

Form

Including active high and active low

1.5 Options

1.5.1 Pulse converter : AK-04

The pulse converter converts command pulses in the open collector mode to those in the

differential mode.

Use this converter if the host controller sends output pulses in the open collector mode.

Item

Specification

Input Power Supply

24V DC �10% (MAX. 50mA)

Input Pulse

O/C (Collector current MAX. 12mA)

Input Frequency

200KHz or less

Output Pulse

Differential output equivalent to 26C31 (MAX. 10mA)�

Mass

10g or less (excluding cable connector)

Accessories

37104-3122-000FL (e-CON Connector) 2 Units

Cover Color : YW

Applicable wire AWG No.24 to 26 (Less than 0.14 to 0.3mm

2

,

finished O.D. �1.0 to 1.2mm)

Caution

1) Use the pulse converter in the ambient temperature range between 0�C and 40�C.

2) The temperature increase of about 30�C occurs during operation. Accordingly,

neither install several pulse converters in close contact nor install them within a

duct. Do not install the pulse converter near other heating devices.

3) If more than one pulse converter is installed, set a pulse converter apart from another by

10mm or more.