Chapter 8 I/O Parameter

231

[116] Zone Output Changeover (Parameter No.149)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

149

Zone Output Changeover

FPIO

0: Not to change

1: To change

0

When there is PZONE signal to the current PIO pattern or the Fieldbus Operation Mode and no

ZONE1 or ZONE2 signal, it is available to change the PZONE signal to either ZONE1 or

ZONE2 signal.

(Note 1) ZONE1 signal is assigned prior to ZONE2 signal.

(Note 2) It would not function in the pulse train mode.

(Note 3) In the case there is no PZONE signal in PIO patterns, or both ZONE1 and ZONE2

signals exist, the setting would be invalid.

[117] Linear Absolute Home Preset Value (Parameter No.150)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

150 Linear Absolute Home Preset

Value

LAPS

mm

-9999.99 to 9999.99

In accordance

with actuator

This can set the home position of the actuator for Spurious Absolute Type.

The diagram below shows the position of each part related to the datum (the initial position at

the delivery from our factory):

(Note 1) Note the initial parameter at the delivery from our factory in a memo before changing

the settings.

(Note 2) Take the initial parameter at the delivery from our factory as the datum when giving a

change to the settings.

(Note 3) After having a change to the settings, make sure to have an operation check with low

speed.

+

+

Slider 2

Slider 1

Slider 2

Slider 2

Slider 1

Slider 1

Stroke

Stroke

Stroke + Slider Length + Min. Distance between Sliders

Coordinates of Slider 2

Coordinates of Slider 1

Slider 2

Positive Side Soft Limit

Slider 1

Negative Side Soft Limit

Slider 1

Positive Side Soft Limit

Slider 2

Negative Side Soft Limit

Min. Distance between Sliders

Min. Distance between Sliders

Datum

(Initial position at the

delivery from our factory)

Slider Length