Chapter 3 Operation

161

[10] Brake Forcible Release (BKRL)

Output

PIO signal

BKRL

The brake can be released while BKRL signal is turned ON.

For the actuator equipped with a brake, the brake can be controlled by turning the servo

ON/OFF, however, a release of the brake may be necessary in the case of installing the unit to

a system so the slider or rod can be moved by hand.

This operation can be performed not only by the brake release switch on the front panel of the

controller, but also by the brake release signal BKRL.

Warning: (1) Take sufficient care to release the brake. Inappropriate brake release

may cause people to be injured and/or the actuator, the work and/or the

machine to be damaged.

(2) After the brake is released, always make the brake applied again. Any

operation with the brake remaining released is extremely dangerous. The

slider or rod may drop to cause people to be injured and/or the actuator,

the work and/or the machine to be damaged.

[11] Overload Alarm/Light Error Alarm (*OVLW/*ALML)

Output

PIO signal

*OVLW/*ALML

Use this with changing the setting in Parameter No.151.

Setting Parameter No.151 to “0” changes to the overload warning output, and it turns OFF

when the motor temperature exceeds the rate set in Parameter No.143 “Overload Level Ratio”.

This signal will be ON as long as the motor temperature does not exceed the warning level.

Setting Parameter No.151 to “1” changes to the light failure alarm output, and it turns OFF

when a message level alarm is generated. This signal will be ON as long as the message level

alarm is not issued.