Chapter 8 I/O Parameter

198

I/O Parameter List (Continued)

No.

C

at

eg

or

y

Name

Symbol

Unit

Input Range

Default factory

setting

for

Positione

r Mode

for Pulse

Train

Mode

Relevant

sections

121 C Feed forward gain 1

PLF1

0 to 100

In accordance

with actuator

(Note2)

8.2 [57]

122 C Velocity Loop Proportional Gain 1

VLG1

1 to 27661

In accordance

with actuator

(Note2)

8.2 [23]

8.3

123 C Velocity Loop Integral Gain 1

VLT1

1 to 217270

In accordance

with actuator

(Note2)

8.2 [24]

8.3

124 C Torque Filter Time Constant 1

TRF1

0 to 2500

In accordance

with actuator

(Note2)

8.2 [25]

8.3

125 C Current control width number 1

CLP1

0 to 4

In accordance

with actuator

(Note2)

8.2 [40]

8.3

126 C Servo gain number 2

PLG2

0 to 31

In accordance

with actuator

(Note2)

8.2 [5]

8.3

127 C Feed forward gain 2

PLF2

0 to 100

In accordance

with actuator

(Note2)

8.2 [57]

128 C Velocity Loop Proportional Gain 2

VLG2

1 to 27661

In accordance

with actuator

(Note2)

8.2 [23]

8.3

129 C Velocity Loop Integral Gain 2

VLT2

1 to 217270

In accordance

with actuator

(Note2)

8.2 [24]

8.3

130 C Torque Filter Time Constant 2

TRF2

0 to 2500

In accordance

with actuator

(Note2)

8.2 [25]

8.3

131 C Current control width number 2

CLP2

0 to 4

In accordance

with actuator

(Note2)

8.2 [40]

8.3

132 C Servo gain number 3

PLG3

0 to 31

In accordance

with actuator

(Note2)

8.2 [5]

8.3

133 C Feed forward gain 3

PLF3

0 to 100

In accordance

with actuator

(Note2)

8.2 [57]

134 C Velocity Loop Proportional Gain 3

VLG3

1 to 27661

In accordance

with actuator

(Note2)

8.2 [23]

8.3

135 C Velocity Loop Integral Gain 3

VLT3

1 to 217270

In accordance

with actuator

(Note2)

8.2 [24]

8.3

136 C Torque Filter Time Constant 3

TRF3

0 to 2500

In accordance

with actuator

(Note2)

8.2 [25]

8.3

137 C Current control width number 3

CLP3

0 to 4

In accordance

with actuator

(Note2)

8.2 [40]

8.3

138 C Servo gain switchover time constant

GCFT

ms

10 to 2000

10

8.2 [108]

139 A Home preset value

PRST

mm

-9999.99 to 9999.99

In accordance

with actuator

(Note2)

8.2 [109]

140 B IP Address

IPAD

0.0.0.0 to

255.255.255.255

192.168.0.1



Separate

volume

141 B Subnet Mask

SNMK

0.0.0.0 to

255.255.255.255

255.255.255.0

Separate

volume

142 B Default Gateway

DFGW

0.0.0.0 to

255.255.255.255

0.0.0.0

Separate

volume

143 B Overload Level Ratio

OLWL

%

50 to 100

100

8.2 [113]

147 B Total Movement Count Threshold

TMCT

Times

0 to 999999999

0 (Disabled)

8.2 [114]

148 B Total Operated Distance Threshold

ODOT

m

0 to 999999999

0 (Disabled)

8.2 [115]

149 B Zone Output Changeover

FPIO

0: Not to change

1: To change

0

8.2 [116]

150 A Linear Absolute Home Preset Value

LAPS

mm

-9999.99 to 9999.99

In accordance

with actuator

8.2 [117]

151 B Light Error Alarm Output Select

FSTP

0:

0: Battery Voltage

Drop Warning

Output

1: Output of

battery voltage

drop warning or

message-level

alarm

8.2 [118]

159 B FB Half Direct Mode

FBVS

0: 1mm/s unit

1: 0.1mm/s unit

0

Separate

volume

Note 2: The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.

Caution: When the controller is operated via serial communication, always set the

controller in the “positioner mode” (piano switch 1: OFF).

If it happens to be in the “pulse train mode” by mistake, the controller may

operate erratically because it is operated according to the “pulse train mode”

parameters.