Chapter 8 I/O Parameter

212

[35] PIO jog velocity 2 (Parameter No.47)

Refer to Section 8.2 [21] for details.

[36] PIO inch distance, PIO inch distance 2 (Parameter No.48, No.49)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

48 PIO inch distance

IOID

mm

0.01 to 1.00

0.1

49

(Note1)

PIO inch distance 2

IOD2

mm

0.01 to 1.00

0.1

When the selected PIO pattern is “1” (teaching mode), this parameter defines the inching

distance to be applied when inching input commands are received from the PLC.

The maximum allowable value is 1 mm.

Note 1 Parameter No.49 “PIO inching distance 2” is not used for the controller.

[37] Load Output Judgment Time Period (Parameter No.50)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

50 Load Output Judgment Time

Period

LDWT

msec

0 to 9999

255

This parameter defines the time taken to judging whether torque level status signal (TRQS) is

ON.

If the command torque exceeds the value set in “Threshold” of position data for the time set by

this parameter during pressing operation, torque level status signal (TRQS) is turned ON.

Refer to 3.2.4 [4] or 3.2.5 [3] Pressing Operation for the details of the pressing operation.

[38] Default acceleration/deceleration mode (Parameter No.52)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

52 Default acceleration/deceleration

mode

CTLF

0 to 2

0 (Trapezoid)

When a target position is written to an unregistered position table, this value is automatically set

as the “Acceleration/deceleration mode” of the applicable position number.

Set Value

Description

0

Trapezoid

1

S-motion

2

Primary delay filter

[39] Default stop mode (Parameter No.53)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

53 Default stop mode

CTLF

0 to 3

0 (Does not use)

This parameter defines the power-saving function.

[Refer to Chapter 6 Power-saving Function.]