2 basic specifications, 1 specifications, Chapter 1 specifications check – IAI America SCON-CA User Manual

Page 33

Advertising
background image

Chapter 1 Specifications Check

23

1.2 Basic Specifications

1.2.1 Specifications

Item

Less than 400W

400W or more

(Note 4)

Corresponding Motor

20W to 399W

400W to 750W

Power-supply Voltage

Single-Phase 100 to 115V AC ±10%

Single-Phase 200 to 230V AC ±10%

Single-Phase 200 to 230V AC ±10%

Power-supply Voltage 100V AC

Rush

Current

(Note 1)

Power-supply Voltage 200V AC

20A (Controller side),

70A (Drive side)

20A (Controller side), 80A (Drive side)

Load Capacity

Refer to Power Capacity and Heat Generation

Leak Current

(Note 2)

3.0mA Primary side when noise filter is connected to power supply line

Heat Generation

Refer to Power Capacity and Heat Generation

Power Supply Frequency

50/60Hz

PIO Power Supply

(Note 3)

24V DC ±10%

Power Supply for Electromagnetic Brake

(for actuator equipped with brake)

24V DC ±10% 1A (MAX.)

(supplied from external equipment)

Transient Power Cutoff Durability

20ms (50Hz), 16ms (60Hz)

Motor Control System

Sine Wave PWM Vector Current Control

Corresponding Encoder

Incremental Serial Encoder

Absolute Serial Encoder

ABZ (UVW) Parallel Encoder

Actuator Cable Length

MAX. 20m

Serial Communication Interface

(Teaching Port)

RS485 : 1CH (based on Modbus Protocol RTU/ASCII)

Speed : 9.6 to 230.4Kbps

Control available with serial communication in the modes other than the pulse train

(Cable length MAX. 100m)

PIO Specifications

Signal I/O dedicated for 24V DC (selected from NPN/PNP) … Input 16 ports max.,

output 16 ports max. Cable length MAX. 10m

External

Interface

Fieldbus Specification DeviceNet/CC-Link/PROFIBUS/CompoNet/MECHATROLINK/EtherCAT/EtherNet/IP …

Each dedicated controller

[Refer to each Fieldbus Instruction Manual]�

Data Setting and Input

PC Software, Touch Panel Teaching, Teaching Pendant

Data Retention Memory

Saves position data and parameters to non-volatile memory

(There is no limitation in number of writing)

Operation Mode

Positioner Mode/Pulse Train Control Mode

(selected by Pulse Train Mode Changeover Switch ON Front Panel)

Number of Positions in Positioner Mode Standard 64 points, MAX. 512 points (PIO Type), 768 points (only for Fieldbus

Type)

(Note) Number of positions differs depending on the selection in PIO pattern and

fieldbus operation mode.

Differential System (Line Driver System) : MAX. 2.5Mpps

Cable length MAX. 10m

Input Pulse

Open Collector Type

: MAX. 200Kpps (under condition AK-04 is used)

Cable length MAX. 2m

Command Pulse

Multiplying Factor

(Electrical Gear : A/B)�

1/50 < A/B < 50/1

Setting Range of A and B (set to parameter) : 1 to 4096

Differential System (Line Driver System) : MAX. 2.5Mpps

Cable length MAX. 10m

Pulse Train

Interface

Feedback Pulse

Output

Open Collector Type

: MAX. 500Kpps (under condition JM-08 is used)

Cable length MAX. 2m

LED Display (mounted on Front Panel)

PWR (green) : Controller in normal condition, SV (green) : Servo ON,

ALM (orange) : Alarm generated,

EMG (red) : Emergency Stop

Electromagnetic Brake Compulsory Release

Switch (mounted on Front Panel)�

Switching NOM (standard)/BK RLS (compulsory release)

Insulation Resistance

500V DC 10M� or more

Insulation Strength

1500V AC for 1 min. (Note) Withstand voltage of pressing operation using force

sensor loadcell is 50V DC

Advertising