2 pulse train control mode, 1] basic wiring diagram, Chapter 2 wiring – IAI America SCON-CA User Manual

Page 67

Advertising
background image

Chapter 2 Wiring

57

2.2 Pulse Train Control Mode

2.2.1 Wiring Diagram (Connection of construction devices)

[1] Basic Wiring Diagram

Actuator

Touch panel teaching (option),

or Teaching pendant (option)

PLC

(Note1)

Regenerative Resistor Unit

(REU-1 [for secondary unit] : option)

Power

Supply

Connector

Flat Cable

(Accessories)

CB-SC-REU010

CB-ST-REU010

FG Connection

Terminal

Regenerative Resistor Unit

(REU-2 : option)

Required depending

on usage condition

[Refer to 1.5.3 Regenerative Unit]

Note 1 Please prepare separately.

JM-08 (option)

Necessary when signal is desired

to be received with open collector output

JM-08 (option)

Necessary when signal is desired

to be received with open collector output

AK-04 (option)

Necessary when PLC is

open collector output

AK-04 (option)

Necessary when PLC is

open collector output

24V DC

24V DC

Cable

(CB-SC-PIOS□□□ : Option)

Cable

(CB-SC-PIOS□□□ : Option)

Power Supply for Brake

It is necessary when actuator with brake

PC Software (option)

(Note1)

Power Source

Single Phase

100V AC or

200V AC

Power Source for

I/O Control

(Note1)

If using RCS-RA13R or NS Type for the actuator and the option shown in the table is applied, the

wiring between the actuator and the controller will differ from the basic wiring layout. Shown in the

table is the relation of the option and wiring layout.

Option

Model Name

Brake

Loadcell

Wiring Layout between Actuator and Controller

×

(1)

RS-RA13R

Ч

Ч

Basic Wiring Diagram

-

(1)

NS

×

-

Basic Wiring Diagram

Caution : Turn OFF the power to the controller before inserting or removing the connector for

connection between the teaching tool and controller.

Inserting or removing the connector while the power is turned ON causes a controller

failure.