Chapter 2 Wiring

42

(3)� List of PIO Signals

The table below lists the functions of PIO signals. Refer to the section shown in Relevant

Sections for the details of the control of each signal.

Category

Signal

Abbreviation

Signal Name

Function Description

Relevant

Sections

CSTR

PTP Strobe

(Start Signal)

The actuator will start to move to the position set by the

command position number.

3.2.4

PC1 to

PC256

Command Position

Number

Input (in binary) a number of the position that is desired to

move.

3.2.4

BKRL

Brake Forcible Release

The brake will forcibly be released.

3.2.3

RMOD

Operation Mode

Changeover

The operating mode is selectable when the MODE switch

of the controller is set to AUTO.

(The setting is AUTO when signal is OFF, and MANU when

ON.)

3.2.3

*STP

Pause

When this signal turns OFF while the actuator is moving,

the actuator will decelerate to stop. The remaining

movement is in a hold while the actuator is stopped and will

resume when the signal turns back ON.

3.2.4

3.2.5

RES

Reset

An alarm will be reset when this signal is turned ON. Also,

when it is turned ON in the pause mode (*STP is turned

OFF), the remaining movement amount can be cancelled.

3.2.3

3.2.4

3.2.5

SON

Servo ON

The servo remains ON while this signal is ON, or OFF while

this signal is OFF.

3.2.3

HOME

Home return

The controller will perform home return operation when this

signal is turned ON

3.2.3

MODE

Teaching mode

The operating mode will change to the teaching mode when

this signal is turned ON. The mode will not be switched over

unless CSTR, JOG+ and JOG- are all OFF and the actuator

operation is stopped.

3.2.4

JISL

Jog/inching selector

Jog Operation can be performed with JOG+ and JOG-

while this signal is OFF.

Inching Operation is performed with JOG+ and JOG- when

it is ON.

3.2.4

JOG +

JOG -

Jog

Jog Operation is performed to positive direction by

detecting ON edge of JOG+ signal and to negative direction

by JOG- signal while JISL signal is OFF.

The actuator will decelerate and stop if OFF edge is

detected while in each Operation.

Inching Operation is performed while JISL signal is ON.

3.2.4

PWRT

Current Position Write

When the write position is specified in the teaching mode

and this signal has remained ON for 20 msec or longer, the

controller will write the current position in the specified

position field.

3.2.4

CLBR

Loadcell Calibration

Command

Turn this signal ON for more than 20ms to perform

calibration of loadcell.

3.2.7

Input

ST0 to ST6 Start Signal

The actuator moves to the commanded position with this

signal ON during the electromagnetic valve mode.

3.2.5

Signal with “*” expresses the signal of active low. In the controller, the process is held when the input signal is turned OFF.