4 alarm list – IAI America SCON-CA User Manual

Page 256

Advertising
background image

Chapter 9

Troubleshooting

246

9.4 Alarm List

Alarm

Code

Alarm

Level

Alarm Name

Cause/Treatment

02E

Calendar function related

command in calendar

function invalid status

Cause

: An attempt was made to use the calendar in the

state where the RTC (calendar) function was made

ineffective.

Treatment : Set parameter No.111 (Selection of use of calendar

function) to “1” (“0”: no use).

048

Driver Overload Alarm

Cause

: The load current exceeded the value set in

Parameter No.143 “Overload Level Ratio”.

This alarm is kept alarm condition until reset is

made. This alarm turns ON when the load current

exceeds the setting from a value below the setting.

Treatment : Lower the setting of acceleration/deceleration. Also,

increase the frequency of pause.

04E

Exceeded movement

count threshold

Cause

: The total number of the operation times exceeded

the value set in Parameter No.147 “Total Movement

Count Threshold”.

04F

Exceeded operated

distance threshold

Cause

: The total number of the operation distance

exceeded the value set in Parameter No.148 “Total

Operated Distance Threshold”.

068

SRAM access error

Cause

: Servo monitor is not operated in the normal

condition because of noise or malfunction of

consisting parts.

Treatment : 1) Take proper measures against noise.

2) When the servo monitoring function is not used,

set parameter No.112 “Monitoring mode” to “0”.

3) If the operation is not improved in use of the

servo monitoring function in spite of measures

against noise, Please contact IAI.

069

Detection of realtime clock

oscillation stop

Cause

: The calendar function is stopped and the current

time data is lost.

Treatment : Set the time again.

[Refer to the Instruction Manual of RC PC software.]

(Note) This error is not registered in the alarm list.

06A

Realtime clock access

error

Cause

: The calendar function is not working properly

because of noise or malfunction of consisting parts.

Treatment : 1) Take proper measures against noise.

2) When the calendar function is not used, set

parameter No.111 “Calendar function” to “0”.

3) If the operation is not improved in use of the

calendar function in spite of measures against

noise, Please contact IAI.

06B

Message

Maintenance information

data error

Cause

: The maintenance information (total movement

count, total operated distance) is lost.

Treatment : Please contact IAI.

Advertising