Chapter 2 Wiring

72

2.3.5 Connection of Pulse Train Signal

Only the plug and the shell are equipped for the standard type.

Perform the same cable layout as the optional connector cable for the pulse train control.

[1] Standard Type (Plug + Shell)

The plug and shell are standard accessory.

Plug : 10114-3000PE (Supplier : 3M)

Shell : 10314-52F0-008 (Supplier : 3M)

The assignment of the signal is the same as [2] Cable for Pulse Control in Option. Refer to

that to perform the connection.

Use the multiple twisted pair shielded cable with AWG24 (0.2mm

2

). When using the cables of

the host controller (PLC, etc.), solder it directly to the connector.

Also, to prevent the noise influence as much as possible, make the cable as short as

possible.

[2] Cable with Connectors for Pulse Train Control (Option)

Model : CB-SC-PIOS��� ��� indicates the cable length Example) 020 = 2m

Cable length : 10m MAX. in differential mode

2m MAX. in open collector mode

Note : There is no connector equipped on the host controller (PLC, etc.) side. Make

an appropriate treatment that suits the host controller (PLC, etc.). Also, to

prevent the noise influence as much as possible, make the cable as short as

possible.

Pin No. 1

Pin No. 8

Plug

Shell

10114-3000PE (Sumitomo 3M)

10314-52F0-008 (Sumitomo 3M)

:

:

CB-SC-PIOS***

Host System Side

AWG24

(0.2mm

2

)

Soldered

Wiring

Color

BK

WT/BK

RD

WT/RD

GN

WT/GN

YW

WT/YW

BR

WT/BR

BL

WT/BL

GY

WT/GY

Symbol

Signal Name

Pulse Train Input

Line Driver Output Line for

Feedback Pulse Output

Shield is connected to the cable clamp

Shield