IAI America SCON-CA User Manual

Page 97

Advertising
background image

Chapter 3 Operation

87

11) Acceleration / deceleration mode ······Select a proper acceleration/deceleration pattern

depending on the load.

Set

Value

Acceleration/

Deceleration Pattern

Operation

0

Trapezoid

1

S-motion

(Refer to Caution at

S-shaped Motion)

Set the S-motion rate with parameter No.56.

2

First-Order

Delay Filter

(Refer to Caution at

First-order Delay Filter)

Set the delay time constant with parameter No.55.

� �

Caution at S-shaped Motion:

1) Since it requires a speed change during the operation, even if having the position

command or direct command that S-shaped motion is set while the actuator is

moving, S-shaped motion control cannot be performed and will be the trapezoid

control.

Make sure to make a command while the actuator is stopped.

2) S-shaped motion control is invalid in the index mode of the rotary actuator.

It will be the trapezoid control even if S-shaped acceleration/deceleration control is

indicated

3) Do not use S-shaped acceleration/deceleration control if the setting of the

acceleration time or the deceleration time exceeds 2 seconds. It will be the

trapezoid control.

4) Do not pause on the move during acceleration or deceleration. It will change the

speed (acceleration) and may cause a danger.

� �

Caution at First-order Delay Filter:

1) Since it requires a speed change during the operation, even if having the position

command or direct command that first-order delay filter is set while the actuator is

moving, first-order delay filter control cannot be performed and will be the trapezoid

control.

Make sure to make a command while the actuator is stopped.

2) First-order delay filter control is invalid in the index mode of the rotary actuator.

It will be the trapezoid control even if first-order delay filter control is indicated

Time

Velocity

Time

Velocity

Time

Velocity

Advertising