Chapter 1 Specifications Check

24

Item

Less than 400W

400W or more

(Note 4)

Weight

Approx. 900g

Approx. 1200g

Cooling Method

Natural Air-Cooling

Forced Air Cooling

External Dimensions

58W × 194H × 121D [mm]

72W × 194H × 121D [mm]

Surrounding air temperature

0 to 40�C

Surrounding humidity

85%RH or less (non-condensing)

Surrounding environment

[Refer to Installation Environment]

Surrounding storage temperature -10 to 65�C
Surrounding storage humidity 85%RH or less (non-condensing)
Usage Altitude

1000m or lower above sea level

Vibration Durability

XYZ Each direction 10 to 57Hz Pulsating amplitude 0.035mm (continuous)

0.075mm (intermittent) 57 to 150Hz 4.9m/s

2

(continuous)

9.8m/s

2

(intermittent)

Environ-

ment

Protection Class

IP20

Note 1 In-rush current will flow for approximately 20ms after the power is turned ON (at 40°C).

Note that the value of in-rush current differs depending on the impedance of the power supply line.

Note 2 Leak current varies depending on the capacity of connected motor, cable length and the surrounding

environment. Measure the leak current at the point where a ground fault circuit interrupter is to be

installed when leakage protection is conducted.

A ground fault circuit interrupter needs to be selected carefully considering the purposes of prevention

of fire and protection of human.

Use the harmonic type (for inverter) for the ground fault circuit interrupter.

Note 3 It is not necessary to supply power to PIO when operating with using ROBONET, Gateway Unit or SIO

Converter without using PIO. In this case, set the parameter No.74 “PIO Power Supply Monitor” to “1”

(Invalid). It will generate the error code No. 0CF “I/O 24V Power Supply Error” if the setting is not done.

Note 4 Some types of linear actuators require a controller of 400W or more even though the motor capacity is

less than 400W.

[Refer to the list of the applicable controllers on the catalog.]