Chapter 1 Specifications Check
24
Item
Less than 400W
400W or more
(Note 4)
Weight
Approx. 900g
Approx. 1200g
Cooling Method
Natural Air-Cooling
Forced Air Cooling
External Dimensions
58W × 194H × 121D [mm]
72W × 194H × 121D [mm]
Surrounding air temperature
0 to 40�C
Surrounding humidity
85%RH or less (non-condensing)
Surrounding environment
[Refer to Installation Environment]
Surrounding storage temperature -10 to 65�C
Surrounding storage humidity 85%RH or less (non-condensing)
Usage Altitude
1000m or lower above sea level
Vibration Durability
XYZ Each direction 10 to 57Hz Pulsating amplitude 0.035mm (continuous)
0.075mm (intermittent) 57 to 150Hz 4.9m/s
2
(continuous)
9.8m/s
2
(intermittent)
Environ-
ment
Protection Class
IP20
Note 1 In-rush current will flow for approximately 20ms after the power is turned ON (at 40°C).
Note that the value of in-rush current differs depending on the impedance of the power supply line.
Note 2 Leak current varies depending on the capacity of connected motor, cable length and the surrounding
environment. Measure the leak current at the point where a ground fault circuit interrupter is to be
installed when leakage protection is conducted.
A ground fault circuit interrupter needs to be selected carefully considering the purposes of prevention
of fire and protection of human.
Use the harmonic type (for inverter) for the ground fault circuit interrupter.
Note 3 It is not necessary to supply power to PIO when operating with using ROBONET, Gateway Unit or SIO
Converter without using PIO. In this case, set the parameter No.74 “PIO Power Supply Monitor” to “1”
(Invalid). It will generate the error code No. 0CF “I/O 24V Power Supply Error” if the setting is not done.
Note 4 Some types of linear actuators require a controller of 400W or more even though the motor capacity is
less than 400W.
[Refer to the list of the applicable controllers on the catalog.]