Chapter 5 vibration suppress control function – IAI America SCON-CA User Manual

Page 187

Advertising
background image

Chapter 5 V

ibration Suppress Control Function

177

Chapter 5 Vibration Suppress Control Function

The vibration suppress control function suppresses vibrations of loads induced by our

actuators.

The function can suppress vibrations in the same direction as the movement of the actuator in

the frequency range from 0.5Hz to 30Hz.

Measure the frequency of the generated vibration and set it to the parameter. Three

frequencies can be defined as parameters. Specify the parameters in the position table to

reflect them on suppression of vibrations generated by the operation. For a single moving

command (position data), only a single parameter can be set.

(Note) Before this function can be used, you must read the cautions described on the next

page.

[Functional Operation]

The figure below shows an example in which two actuators are subject to 2-axis combination.

Actuator A is moved to cause actuator B corresponding to a joint to be vibrated. Measure the

vibrations of B in the direction in which A is moved and make proper vibration suppress control

in the direction to suppress the vibrations of B. Vibrations of actuator B caused by the

movement of B cannot be suppressed.

A

A

B

(Joint)

B

(Joint)

Vibration in axis

moving direction

No setting of vibration suppress control

Setting of vibration suppress control