Precautions in operation – IAI America SCON-CA User Manual

Page 18

Advertising
background image

8

Precautions in Operation

1. Use the following teaching tools.

Use the PC software and the teaching pendant stated in the next clause as the applicable for

this controller.

[Refer to 1.1.2 Teaching Tool.]

2. Backup the data to secure for breakdown.

A non-volatile memory is used as the backup memory for this controller. All the registered

position data and parameters are written into this memory and backed-up at the same time.

Therefore, you will not usually lose the data even if the power is shut down. However, make

sure to save the latest data so a quick recovery action can be taken in case when the controller

is broken and needs to be replaced with another one.

How to Save Data

(1) Save the data to CD-R or hard disk with using the PC software

(2) Hard-copy the information of position tables and parameters on paper

3. Set the operation patterns.

This controller processes 9 types of control logics (including 8 types of PIO patterns and pulse

train control) to meet various ways of usage, and changes the role of each PIO signal following

the selected control logic.

The setup can be performed by using the operation mode change switch or parameter No.25

“PIO pattern selection” on the front panel.

[Refer to Chapter 3 Operation and Chapter 8 I/O Parameter.]

The PIO pattern is set to “0” (Standard Type) when the unit is delivered. Set the operation

pattern setting to the logic that suits to your use after the power is turned on.

4. Clock Setting in Calendar Function

There may be a case that Alarm Code 069 “Real Time Clock Vibration Stop Detect” is issued at

the first time to turn the power on after the product is delivered. In the case this happens, set the

current time with a teaching tool.

If the battery is fully charged, the clock data is retained for approximately 10 days after the

power is turned OFF. Even though the time setting is conducted before the product is shipped

out, the battery is not fully charged. Therefore, there may be a case that the clock data is lost

even with fewer days than described above passed since the product is shipped out.

5. In pulse train control mode, actuator operation is unavailable through serial

communication.

In the pulse train control mode, the actuator operation is unavailable through serial

communication. (The field bus specification does not meet the pulse train control mode.)

However, it is possible to monitor the current status.

Warning :

Please note it is very risky when the control sequence and PIO pattern setting do not match to

each other. It may not only cause the normal operation disabled, but also may cause an

unexpected.

Advertising