Chapter 10 appendix, Detailed category 1 circuit example – IAI America SCON-CA User Manual

Page 273

Advertising
background image

Chapter 10

Appendix

263

Detailed category 1 circuit example

SG

SGA

SGB

RTS

CTS

EMG1-

EMG1+

EMG2-

EMG2+

EMB1-

EMB1+

EMB2-

EMB2+

DC24V+

DC24V-

EMBOUT

EMBIN

EMB2+

EMB2-

EMB1+

EMB1-

EMGOUT

EMGIN

EMG2+

EMG2-

EMG1+

EMG1-

1

2

3

4

5

6

7

8

9

1

2

3

4

System I/O

Connector

Enable SW

SW Reset

SW

Emergency

Stop

24V

24V

Solenoid Contactor

100V AC/

200V AC

DC Bus

L1
L2

E24V

*EMGSTR

EMGRYRLS

EMGSTR

VP24

SCON

TP Connection Detecting

TP Detection

T24V…Output

Bypass relay…OPEN

TP Not Detected

T24V…Not Output

Bypass relay…CLOSE

TP

Emergency Stop SW

Enable SW

Shell

1

2

3

13

14

9

12

6

5

23

24

25

22

7

26

12

11

10

9

8

7

6

5

4

3

2

1

External Emergency

Stop Circuit

Category 1

Motor Power

Cutoff Relay

Regulator

RCB-LB-TG

SGA

SGB

EMGA

T24V

EMGB

1

2

3

4

5

6

7

8

9

5V

+

Advertising