Chapter 8 I/O Parameter

200

[2] Soft limit�+, Soft limit�– (Parameter No.3, No.4)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

3

Soft limit +

LIMM

mm

(deg)

-9999.99 to

9999.99

Actual stroke on +

side

4

Soft limit –

LIML

mm

(deg)

-9999.99 to

9999.99

Actual stroke on -

side

0.3mm (deg) is added to the outside of the effective actuator stroke for the setting at the

delivery (since there would be an error at the end of effective stroke if set to 0). Change the

setting if required for the cases such as when there is interference or to prevent a crash, or

when using the actuator with slightly exceeding effective stroke in the operational range.

An incorrect soft limit setting will cause the actuator to collide into the mechanical end, so

exercise sufficient caution.

The minimum setting unit is 0.01mm.

(Note) To change a soft limit, set a value corresponding to 0.3mm outside of the effective

stroke.

Example) Set the effective stroke to between 0mm and 80mm

Parameter No.3 (positive side) 80.3

Parameter No.4 (negative side) -0.3

Approx. 0.3mm

Approx. 0.3mm

Soft limits set in the parameter

Effective stroke

Allowable jogging/inching range after home return

0.2mm

0.2mm

The operational range for jog and inching after the home return is 0.2mm less than the set

value.

Alarm Code 0D9 “Soft Limit Over Error” will be generated when the set value exceeded the

value (0 when shipped out) set in Parameter No.88 “Software Limit Margin”. If the setting is not

done in Parameter No.88, the value set in this parameter become the detection value for Alarm

Code 0D9 “Soft Limit Over Error”.

[3] Home Return Direction (Parameter No.5)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

5

Home Return Direction

ORG

0: Reverse

1: Forward

In accordance with

actuator

Unless there is a request of Home Reversed Type (option), the home-return direction is on the

motor side for the line axis, counterclockwise side for the rotary axis and outer (open) side for

the gripper. [Refer to the coordinate system of the actuator.]

If it becomes necessary to reverse the home direction after the actuator is installed on the

machine, change the setting.

Caution: For the actuator of rod or rotary type, the home direction cannot be changed.