1.2

< EXAxt ZR > System Components

1.2.1

System Components

T1-1E.ai

System Components

Model ZR22G Separate type Zirconia Oxygen Analyzers ,Detector
Model ZR402G Separate type Zirconia Oxygen Analyzer, Converter

Model ZO21P Adapter for High Temperature Probe of separate type Zirconia Oxygen Analyzer

E7046EC, E7046EN Ejector Assembly for High temperature of separate type Oxygen Analyzer

Model ZO21R Probe Protector for Zirconia Oxygen Analyzers
K9471UA Dust Filter for Oxygen Analyzer

Model ZO21S Standard Gas Unit
Model ZA8F Flow Setting Unit for manual calibration
Model ZR40H Automatic Calibration Unit for Separate type Oxygen Analyzer

L9852CB, G7016XH Stop Valve for Calibration gas line

K9292DN,K9292DS Check Valve for Calibration gas line
G7003XF/K9473XK, G7004XF/K9473XG Air Set

G7001ZC Zero gas Cylinder
G7013XF, G7014XF Pressure Reducing Valve for Gas Cylinder

E7044KF Case Assembly for Calibration gas Cylinder

Separate type

Ex.1 Ex.2 Ex.3

System config.

: Items required for the above system example
: To be selected depending on each application. For details, refer to corresponding chapter.
: Select either

( )

( )

( )

Model ZR22A Heater Assembly (Spare Parts for Model ZR22G)

K9471UC Dust Guard Protector

1.2.2

Detectors and Accessories

Detector

(ZR22G)

Detector

(ZR22G)

Detector(ZR22G)

Probe Protector

(ZO21R)

Gas Flow

F06.ai

+

Sample gas temperature 0 to 700°C

Sample gas temperature 700 to 1400˚C

Mounting

Insertion

length

General use Probe

High temperature detector

Application

Application

Horizontal

to

vertical

Horizontal

to

vertical

Horizontal

to

vertical

Vertical

Vertical

0.15

to

2 m

0.15

to

2 m

2.5 m

or more

3 m

or less

2.5 m

or more

Boiler

Heating

furnace

For pulverized

coal boiler

with gas flow

velocity

10 m/sec or

more

Black liquid

recovery boiler

Cement

Kiln

Sample inlet

Sample

outlet

Sample inlet

High temperature

detector

Heating

furnace

Temperature:

Probe material: SUS310S 800˚C

Probe material: SiC 1400˚C

Mounting: Vertical downwards

Insertion length: 1.0 m, 1.5 m

When duct pressure is atmospheric

or negative, attach air ejector.

High temperature auxiliary ejector

assembly (E7046EC, E7046EN)

Pressure gauge

Needle

valve

Blow

Absorption

structure

Inlet

Ejector

Probe adapter

for high

temperature use

ZO21P-H

Dust filter for

Oxygen Analyzer

(K9471UA)

Dust guard

protector

(K9471UC)

or