Model and Codes

Style : S2

Model

Suffix code

Option code

Description

ZR22G

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Separate type Zirconia Oxygen Analyzer, Detector

Length

-015

-040

-070

-100

-150

-200

-250

-300

-360

-420

-480

-540

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

0.15 m (for high temperature use) (*1)

0.4 m

0.7 m

1.0 m

1.5 m

2.0 m

2.5 m (*2)

3.0 m (*2)

3.6 m (*2)

4.2 m (*2)

4.8 m (*2)

5.4 m (*2)

Wetted material

-S

-C

- - - - - - - - - -

- - - - - - - - - -

SUS316

Stainless steel with Inconel calibration gas tube (*10)

Flange

(*3)

-A

-B

-C

-E

-F

-G

-K

-L

-M

-P

-Q

-R

-S

-W

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

ANSI Class 150 2 RF SUS304

ANSI Class 150 3 RF SUS304

ANSI Class 150 4 RF SUS304

DIN PN10 DN50 A SUS304

DIN PN10 DN80 A SUS304

DIN PN10 DN100 A SUS304

JIS 5K 65 FF SUS304

JIS 10K 65 FF SUS304

JIS 10K 80 FF SUS304

JIS 10K 100 FF SUS304

JIS 5K 32 FF SUS304 (for high temperature use) (*4)

JPI Class 150 4 RF SUS304

JPI Class 150 3 RF SUS304

Westinghouse

Reference gas

-C

-E

-P

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

Natural convection

External connection (Instrument air) (*11)

Pressure compensated (*11)

Gas Thread

-R

-T

- - - - - - - - - -

- - - - - - - - - -

Rc 1/4

1/4 NPT(Female)

Connection box thread

-P

-G

-M

-T

-Q

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

G1/2

Pg13.5

M20 x1.5 mm

1/2NPT

Quick connect (*9)

Instruction manual

-J

-E

-C

- - - - - - - - - -

- - - - - - - - - -

- - - - - - - - - -

Japanese

English

Chinese

-A - - - - - - - - - -

Always -A

Options

Valves

Filter

Tag plates

/C

Inconel bolt (*5)

/CV

/SV

Check valve (*6)

Stop valve (*6)

/F1

/F2

Dust Filter (*7)

Dust Guard Protector (*7)

/SCT

/PT

Stainless steel tag plate (*8)

Printed tag plate (*8)

*1

Used with the ZO21P High Temperature Probe Adapter. Select flange (-Q).

*2

When installing horizontally the probe whose insertion length is 2.5 meters or more, use the Probe Protector. Be sure to

specifyZO21R-L-200-

. Specify the flange suffix code either -C or -K.

*3

The thickness of the flange depends on its dimensions.

*4

Not used in conjunction with -P (pressure compensation) for reference gas. The flange thickness does not conform to JIS

specification

*5

Inconel probe bolts and U shape pipe are used. Use this option for high temperature use (ranging from 600 to 700 °C).

*6

Specify either /CV or /SV option code.

*7

Not used with the high temperature humidity analyzer.

*8

Specify either /SCT or /PT option code.

*9

Not waterproof, avoid rain. Operating maximum temperature is 80°C. Available only in the U.S.

*10 Recommended if sample gas contains corrosive gas like chlorine.