Rockwell Automation 865 Differential Protection Relay User Manual

Page 4

Advertising
background image

ii

Table of Contents

865-UM001A-EN-P – July 2009


Retardation Time .............................................................. 3-3

Reset Time (Release Time) .............................................. 3-4

Hysteresis or Dead Band .................................................. 3-5

Differential Overcurrent Protection ΔI> (87) ......................... 3-6

Parameters of the Differential Overcurrent Stages ......... 3-10

Overcurrent Protection I> (50/51) ........................................ 3-11

Two Independent Stages ................................................ 3-11

Inverse Operation Time .................................................. 3-11

Inverse Time Limitation ................................................. 3-11

Setting Groups ................................................................ 3-11

Recorded Values of the Latest Eight Faults ................... 3-14

Current Unbalance Protection I

2

>, I’

2

(46) ........................... 3-15

Inverse Delay ................................................................. 3-15

More Stages (Definite Time Delay only) ....................... 3-15

Setting Groups ................................................................ 3-15

Recorded Values of the Latest Eight Faults ................... 3-17

Earth Fault Protection I

0

> (50N/51N) ................................... 3-17

Input Signal Selection .................................................... 3-18

Intermittent Earth Fault Detection .................................. 3-18

Four Independent Undirectional Earth Fault

Overcurrent

Stages

...................................................

3-18

Inverse Operation Time (I

0

> stage only) ........................ 3-19

Inverse Time Limitation ................................................. 3-19

Setting Groups ................................................................ 3-19

Recorded Values of the Latest Eight Faults ................... 3-22

Thermal Overload Protection T> (49) .................................. 3-22

Thermal Model ............................................................... 3-22

Time Constant for Cooling Situation ............................. 3-23

Heat Capacitance, Service Factor and Ambient Temp. ...3-23

Example of a Behavior of the Thermal Model ............... 3-24

Initial Temperature Rise after Restart ............................ 3-24

Alarm Function .............................................................. 3-24

Circuit-Breaker Failure Protection CBFP (50BF) ................ 3-26

Recorded Values of the Latest Eight Faults .......................... 3-27

Arc Fault Protection (50ARC/50NARC) - Optional ............ 3-28

Three Stages for Arc Faults ............................................ 3-28

Light Channel Selection ................................................. 3-28

Binary Input ................................................................... 3-28

Binary Output ................................................................. 3-29

Delayed Light Indication Signal .................................... 3-29

Pick Up Scaling .............................................................. 3-29

Recorded Values of the Latest Eight Faults ................... 3-30

Programmable Stages (99) .................................................... 3-31

Available Signals to be Supervised by the

Programmable

Stages

..............................................

3-31

Eight Independent Stages ............................................... 3-31

Setting Groups ................................................................ 3-31

Recorded Values of the Latest Eight Faults ................... 3-32

Chapter 3

Protection

Functions

(cont.)

Advertising