Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

107

Connecting the Kinetix 6000 Drive System

Chapter 5

These cables contain only the three-phase power wires. The motors/actuators
either have no brake or a separate connector for brake connections. Thermal
switch wires are included in the feedback cable.

Refer to Axis Module/Rotary Motor Wiring Examples beginning on

page 196

for interconnect diagrams.

Figure 56 - Motor Power Terminations (cables without brake wires)

The cable shield clamp shown above is mounted to an IAM module. Cables
attach to the clamp on each AM module in the same way.

CTRL 2

CTRL 1

DC-

DC+

L3

L2

L1

CONT EN-

CONT EN+

BAUD

RATE

TX

RX

DPI

W

V

U

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

1 2 3 4

Motor Cable

Shield Clamp

Motor Power (MP) Connector Plug

Kinetix 6000
IAM/AM Module
(IAM module is shown)