Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

251

Changing the Default IDN Parameter Values

Appendix E

In this example, the Message Configuration (MSG) instruction is set to
read the additional bus capacitance of your leader IAM power module.

a. From the Message Type pull-down menu, choose sercos IDN Read.

b. From the Identification Number pull-down menus, choose P-0-99.

3. Click New Tag.
4. The New Tag dialog box opens.

5. Type the name of your Destination tag.

In this example, the tag name is Read_Value.

6. Click OK.

In this example, the MSG instruction reads the P-0-99 IDN value and
places it in the destination as specified by the new tag.

7. Click the Communication tab.