Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual

Page 109

Advertising
background image

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

109

Connecting the Kinetix 6000 Drive System

Chapter 5

The 1326AB (resolver) power cables (catalog number 1326-CP

x1T-L-xxx)

contain the three-phase wires, brake wires, and thermal switch wires. To improve
the EMC performance of your system, route the wires as shown.

Refer to Axis Module/Rotary Motor Wiring Examples beginning on

page 196

for interconnect diagrams.

Figure 58 - Motor Power Terminations (1326-CPx1T-L-xxx cable)

The cable shield clamp shown above is mounted to an IAM module. Cables
attach to the clamp on each AM module in the same way.

DC-

DC+

L3

L2

L1

CONT EN-

CONT EN+

CTRL 1

CTRL 2

W

V

U

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

1 2 3 4

1 2 3 4 5 6

BAUD

RATE

TX

RX

DPI

Thermal Switch
Wires

Keep wires separated

as much as possible.

Resistive/Motor Brake
(BC) Connector

Motor Power
(MP) Connector

Terminal Block (mounted on DIN rail)
Refer to

page 35

for treatment of painted panels.

Low-profile motor feedback connector

(2090-K6CK-D15MF) pins 16, 17, and S

provide filtering for 1326-CPx1T-L-xxx cables

(refer to

page 124

for an illustration).

MF-16
MF-17

MF-S

Thermal Switch Wires

Kinetix 6000 IAM/AM Module
(IAM module is shown)

Motor Cable Shield

Clamp

IMPORTANT

We recommend securing the cable shield in the clamp with a tie wrap to
improve stress relief.

Advertising