Connecting the Kinetix 6000 Drive System

Chapter 5

Figure 44 - Setting the Ground Jumper (460V Series A IAM modules)

P13

P14

P12

P13

P14

P12

Bottom Screw

Front Panel (opened)

Ground jumper set

for grounded configuration

(default setting).

Ground jumper set
for ungrounded configuration.

Top Screw

Bottom Screw

Front Panel (opened)

Ground jumper set

for grounded configuration

(default setting).

Ground jumper set
for ungrounded configuration.

Top Screw

2094-BC04-M03-x or
2094-BC07-M05-x
IAM Module (460V)

2094-BC01-MP5-x,
2094-BC01-M01-x, or
2094-BC02-M02-x
IAM Module (460V)

IMPORTANT

Use the default jumper setting or remove the jumper entirely for grounded
power configurations. Move the jumper, as shown above, for ungrounded
power.