Enhanced Peak Performance

This appendix provides procedures and information, specific to the Kinetix 6000
drive systems, for enabling the peak enhancement feature in each drive.

Before You Begin

The peak current ratings of the Kinetix 6000 460V drives (series A, B, and C) are
configured at the factory as 150% of continuous current. However, you can
program 460V (series B and C) AM modules and the equivalent IAM (inverter)
modules, for up to 250% of continuous inverter current.

To achieve the enhanced peak performance, you must determine the values of
maximum acceleration, deceleration, and torque. This feature is present only in
the Kinetix 6000 (series B and C) drives listed in

Table 128

.

Table 128 - Kinetix 6000 Series Change

Topic

Page

Before You Begin

255

Enhanced Peak Example

257

Change the Drive Parameter

262

IAM Module
Cat. No.

AM Module
Cat. No.

Peak Current Rating

Series A (inverter)

Series B and C (inverter)

2094-BC01-MP5-S

2094-BMP5-S

150%

250%

2094-BC01-M01-S

2094-BM01-S

150%

250%

2094-BC02-M02-S

2094-BM02-S

150%

250%

2094-BC04-M03-S

2094-BM03-S

150%

250%

2094-BC07-M05-S

2094-BM05-S

150%

200%

Advertising