Figure 93 - Leader IAM Module with Multiple Follower IAM Modules (continued)

CONT EN-

CONT EN+

W

V

U

DC-

DC+

L3

L2

L1

CTRL 2

CTRL 1

1

2

1

2

3

4

5

6

1

2

6

5

4

3

2

1

4

3

2

1

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

N.C.

N.C.

N.C.

CONT EN-

CONT EN+

W

V

U

DC-

DC+

L3

L2

L1

CTRL 2

CTRL 1

1

2

1

2

3

4

5

6

1

2

6

5

4

3

2

1

4

3

2

1

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

N.C.

N.C.

N.C.

Note 4

* Indicates User Supplied Component

From Leader

Control Circuit

Connections

From Leader

Control Power

Connections

From Leader

DC Bus Connections

Control Power
(CPD) Connector

Contactor Enable
(CED) Connector
Note 14

Motor/Resistive

Brake (BC) Connector

Three-phase
Motor Power
Connections
Note 16

Motor Power

(MP) Connector

Cable Shield

Clamp

Note 10

2094-ACxx-Mxx-x or

2094-BCxx-Mxx-x

Common-bus Follower

IAM Module

Power Rail
Ground Stud

DC Bus
and
Three-phase
Input (IPD)
Connector

Bonded Cabinet

Ground Bus *

Note 4

Control Power
(CPD) Connector

Contactor Enable
(CED) Connector
Note 14

Motor/Resistive

Brake (BC) Connector

Three-phase
Motor Power
Connections
Note 16

Motor Power

(MP) Connector

Cable Shield

Clamp

Note 10

2094-ACxx-Mxx-x or

2094-BCxx-Mxx-x

Common-bus Follower

IAM Module

Power Rail
Ground Stud

DC Bus
and
Three-phase
Input (IPD)
Connector

Bonded Cabinet

Ground Bus *

DC Bus Fusing *

Note 2

DC Bus Fusing *

Note 2

Refer to table on

page 186

for note information.

Advertising