Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

261

Enhanced Peak Performance

Appendix F

6. Click Set Custom Limits.

7. Overwrite the existing AccelerationLimitBipolar value.

In this example, the calculated value is 668.18.

8. Overwrite the existing AccelerationLimitPositive and

AccelerationLimitNegative values.

In this example, the calculated values are +668.18 and -668.18
(respectively).

9. Repeat this process for each IAM and AM module in your system.

Default AccelerationLimitBipolar Value

Default AccelerationLimitPositive and

AccelerationLimitNegative Values