Rockwell Automation Publication 2094-UM001H-EN-P - June 2013
Chapter 5
Connecting the Kinetix 6000 Drive System
Figure 45 - Setting the Ground Jumper (460V Series B and C IAM modules)
P16
P17
P18
P19
(behind P18)
P18
P19
Bottom Screw
Front Panel (opened)
Ground jumper set
for grounded configuration
(default setting).
Ground jumper set for
ungrounded configuration.
Top Screw
2094-BC01-MP5-S,
2094-BC01-M01-S,
2094-BC02-M02-S,
2094-BC04-M03-S, or
2094-BC07-M05-S
IAM Module (460V)