Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual

Page 96

Advertising
background image

96

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

Chapter 5

Connecting the Kinetix 6000 Drive System

Table 59 - IAM/AM Power Wiring Requirements

Table 60 - Shunt Module Power Wiring Requirements

Kinetix 6000 Drive
Cat. No.

Description

Connects to Terminals

Recommended
Wire Size
mm

2

(AWG)

Strip Length
mm (in.)

Torque Value
N•m (lb•in)

Pin

Signal

2094-AC05-Mxx-x,
2094-AC09-M02-x,
2094-BC01-Mxx-x,
2094-BC02-M02-x,
2094-AMP5-x, 2094-AM01-x,
2094-AM02-x, 2094-BMP5-x,
2094-BM01-x, 2094-BM02-x

Motor power

MP-4
MP-3
MP-2
MP-1

Motor power cable
depends on motor/
drive combination.

6…1.5
(10…16)

10 (0.38)

0.5…0.6
(4.4…5.3)

2094-AC16-M03-x,
2094-AC32-M05-x,
2094-BC04-M03-x,
2094-AM03-x, 2094-AM05-x,
2094-BM03-x

10…1.5
(8…16)

10 (0.38)

1.2…1.5
(10.6…13.2)

2094-BC07-M05-x,
2094-BM05-x

30…2.5
(3…14)

16 (0.63)

2.4…3.0
(21.6…26.5)

IAM or AM
(230 or 460V)
2094-xCxx-Mxx-x and
2094-xMxx-x

Brake power

BC-6
BC-5
BC-4
BC-3
BC-2
BC-1

MBRK-
MBRK+
COM
PWR
DBRK-
DBRK+

0.75 (18)

10 (0.38)

0.22…0.25
(1.9…2.2)

IAM or AM
(230 or 460V)
2094-xCxx-Mxx-S and
2094-xMxx-S

Safe torque-off

STO-1
STO-2
STO-3
STO-4
STO-5
STO-6
STO-7
STO-8
STO-9

FDBK2+
FDBK2-
FDBK1+
FDBK1-
SAFETY ENABLE2+
SAFETY ENABLE-
SAFETY ENABLE1+
24V +
24V_COM

0.75 (18)
(stranded wire with
ferrule)

1.5 (16)
(solid wire)

7.0 (0.275)

0.235 (2.0)

W
V
U

Drive Module Cat. No.

Description

Connects to Terminals

Recommended
Wire Size
mm

2

(AWG)

Torque Value
N•m (lb•in)

Pin

Signal

2094-BSP2
Shunt module
(200/400V-class)

1394-SRxxxx
External passive shunt
module

RC-1

DC+

10 (8)

(1)

1.2…1.5
(10.6…13.2)

RC-2

INT

RC-3

COL

Thermal switch

TS-1

TS1

0.75 (18)

0.22…0.25
(1.9…2.2)

TS-2

TS2

(1) 105 °C (221 °F), 600V.

Advertising