Configure and Start the Kinetix 6000 Drive System

Chapter 6

6. Click the sercos Interface tab and reference the table below.

7. Verify that the Data Rate setting matches DIP switches 2 and 3

(communication rate), as set on the IAM and AM module, or choose the
Auto Detect setting.

8. From the Cycle Time pull-down menu, choose the Cycle Time according

to the table below.

9. From the Transmit Power pull-down menu, choose High.

The default setting is High, however this setting is dependent on the cable
length (distance to next receiver) and cable type (glass or plastic).

10. Enter the Transition to Phase setting.

The Transition to Phase default setting is 4 (phase 4). The Transition to
Phase setting stops the ring in the phase specified.

11. Click OK.
12. Repeat

step 1

through

step 11

for each Logix5000 module.

Logix5000 Sercos Module

Number of Axes

Data Rate

1756-M03SE or
1756-L60M03SE

Up to 3

4 or 8 Mbps

1756-M08SE

Up to 8

1756-M16SE or
1784-PM16SE

Up to 16

1768-M04SE

Up to 4

Data Rate

Number of Axes

Cycle Time

4 Mbps

Up to 2

0.5 ms

Up to 4

1 ms

Up to 8

2 ms

No support for axes 9…16

8 Mbps

(1)

(1) The Kinetix 6000M IDM system supports only 8 Mbps and is hardwired for this setting.

Up to 4

0.5 ms

Up to 8

1 ms

Up to 16

2 ms

TIP

The number of axes/module is limited to the number of axes as
shown in

step 6

.