Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual

Page 108

Advertising
background image

108

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

Chapter 5

Connecting the Kinetix 6000 Drive System

These cables contain three-phase power wires and brake wires. The brake wires
have a shield braid (shown below as gray) that folds back under the cable clamp
before the conductors are attached to the motor brake (BC) connector. Thermal
switch wires are included in the feedback cable.

Refer to Axis Module/Rotary Motor Wiring Examples beginning on

page 196

for interconnect diagrams.

Figure 57 - Motor Power Terminations (cables with brake wires)

The cable shield clamp shown above is mounted to an IAM module. Cables
attach to the clamp on each AM module in the same way.

DC-

DC+

L3

L2

L1

CONT EN-

CONT EN+

CTRL 2

CTRL 1

W

V

U

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

1 2 3 4

1 2 3 4 5 6

BAUD

RATE

TX

RX

DPI

Resistive/Motor Brake
(BC) Connector

Motor Power
(MP) Connector

Motor Cable Shield

Clamp

Kinetix 6000
IAM/AM Module
(IAM module is shown)

MP-Series Cable

Brake Wires

Advertising