Chapter 5

Connecting the Kinetix 6000 Drive System

When connecting 2094-BM03-

x and 2094-BM05-x (double-wide) axis modules,

use 2090-SCEP0-2, 0.2 m (7.0 in.) cables. When connecting 2094-AM

xx-x,

2094-BMP5-

x, 2094-BM01-x, and 2094-BM02-x (single-wide) axis modules,

use 2090-SCEP0-1, 0.1 m (5.1 in.) cables.

Figure 76 - Fiber-optic Cable Example - Logix5000 Controller with Double-wide Drive Modules

In this example, the second Kinetix 6000 system is mounted in a separate cabinet
and connected with bulkhead adapters.

Figure 77 - Fiber-optic Cable Example - Logix5000 Controller with Bulkhead Adapters

SERCOS interface

TM

Tx (rear)

Rx (front)

OK

CP

0.1 m

(5.1 in.)

0.2 m

(7.1 in.)

1756-M16SE Sercos

Interface Module

Sercos Fiber-optic Ring

Kinetix 6000 System
(5-axis power rail)

Logix5000 Controller

(ControlLogix controller is shown)

IMPORTANT

To avoid signal loss, do not use bulkhead adapters to connect glass cables. Use
only bulkhead adapters for making plastic-to-plastic cable connections.

SERCOS interfaceTM

Tx (rear)

Rx (front)

OK

CP

1756-MxxSE Sercos
Interface Module

Sercos Fiber-optic
Bulkhead Adapter

Sercos Fiber-optic Ring

Sercos Ring

Sercos Fiber-optic
Bulkhead Adapter

Kinetix 6000

System

Kinetix 6000
System

Logix5000 Controller
(ControlLogix controller is shown)

Transmit

Receive

Transmit

Receive

Receive

Transmit

Cabinet

Advertising