Sets of Angles

• Measure Set

At the conclusion of the learning
phase, select Measure Further Set.
You will be prompted to make the
measurements, in the sequence you
selected in Configuration, to
complete the first Set of
measurements.

- Non-motorized instruments will

display the Telescope Positioning
dialog to help you find the target
points in sequence.

- Motorized instruments will

automatically turn to the target
points in sequence. You must
refine the pointing manually. After
completing the first set, the
program returns to the Sets Menu.

- With TCA- or TCRA-instruments

and Auto. Meas. = ON, the first set
will be completed automatically
and the program returns to the
Sets Menu.

Set no.
Displays the number of the set
currently being measured.

Seq. no.
Displays the sequential number of
the point currently being measured.

Face
Displays the required instrument face
for this measurement.

You will use this dialog to measure all
additional sets at this instrument
station.

Measure Mode, continued

Point Id
Displays the Point Id of the point
currently being measured.

Refl. Ht.
Displays the Reflector Height of the
point currently being measured.

SETS\

Measure Set

Set No.

:

1

Seq. No.

:

1

Face

:

I

Point Id

:

501

Refl. Ht. :

1.300 m

MC

QUIT

MEAS

<--

-->

DONE