Configuration, Configuration editor, Dual-face measurement – Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual

Page 134: Configuration editor dual-face measurement, Traverse

Advertising
background image

134

TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Traverse

Configuration Editor

Start the "Configuration Editor" from
the "traverse menu" dialog.

Configuration

Code
Input the code number used when
recording results in the Meas Job
(max. 8 characters).

Log File
Set to ON, the program will record
measurement data in the Log File
according to the format described on
chapter Log File.

Log FlName
Enter the Log File Name.

Accept the displayed
parameters and return to the

"TRAVERSE MENU".

Set all values to default.
Default values are shown in

dialog.

Display the Traverse
Information dialog.

The "Configuration Editor" sets
parameters for further program
operations:

Two Faces
YES for dual-face measurement
NO

for single-face.

Mult.Meas
YES to allow multiple measurements,
NO

for single measurement.

Dual-face Measurement

In the dual-face mode, the program
will prompt for measurements in both
faces. When both measurements are
taken, the program will check the
difference between the two. If the
difference in angle is within 27'
(0.5 gon)
and the difference of two
measured distances is within 0.5 m
(1.64 ft)
, the observations will be
averaged. These tolerances are used
to avoid errors in target identification.
If exceeded an error message will be
displayed.

Trav\

Configuration

Two Faces :

NO

Mult.Meas :

NO

Code

:

38

Log File

:

OFF

Log FlName:

TRAVERSE.LOG

Meas Job

:

FILE01.GSI

MC

CONT

DEFLT INFO

QUIT

Data Job

:

FILE01.GSI

Advertising