Reference plane menu, Introduction, continued – Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual
Page 257

257
TPS1100 - Appl. Prog. Ref. Manual 2.2.0en
TQM
The max. allowed deviation of these
points from the plane can be set in
the Configuration dialog.
Once the plane has been defined it
can be shifted by an entered offset.
Alternatively it can be shifted through
a measured point.
Plane information as well as
measured points can be recorded in
a Logfile.
Reference Plane Menu
The coordinate system is selected in
the beginning.
Local Coordinates
After measuring the points to define
the plane the user can enter local
coordinates for the first point. This
sets the local coordinate system. All
points are calculated in it.
Instrument Coordinates
All points are calculated and
recorded in the instrument coordinate
system.
For Instrument Coordiantes
station must be setup and
oriented.
Introduction, continued
REFP\ Reference Plane
1 Local Coordinates
2 Instrument Coordinates
MC
CONT
CONF